Kontaktujte nás | Jazyk: čeština English
dc.title | Proposal and verification of a methodology for the measurement of local muscular load via datalogger | en |
dc.contributor.author | Molnár, Vieroslav | |
dc.contributor.author | Fedorko, Gabriel | |
dc.contributor.author | Tuček, David | |
dc.contributor.author | Tučková, Zuzana | |
dc.relation.ispartof | Measurement: Journal of the International Measurement Confederation | |
dc.identifier.issn | 0263-2241 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2018 | |
utb.relation.volume | 121 | |
dc.citation.spage | 73 | |
dc.citation.epage | 82 | |
dc.type | article | |
dc.language.iso | en | |
dc.publisher | Elsevier | |
dc.identifier.doi | 10.1016/j.measurement.2018.02.009 | |
dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S0263224118300952 | |
dc.subject | Carpal tunnel syndrome | en |
dc.subject | Datalogger | en |
dc.subject | Ergonomics | en |
dc.subject | Integrated electromyography (EMG) | en |
dc.subject | Local muscular load | en |
dc.description.abstract | Workers are under increasing pressure to perform, and an encouraging working environment must be created so as to help ensure that workers meet their performance goals. Despite the growing trend of automation and robotics, the human factor remains important. This paper studies occupational diseases stemming from long-term, excessive, and unilateral muscular load in employees. The paper's aim is to evaluate the “local muscular load” that is measured in Czech and Slovak businesses, and to verify the local muscular load measuring methodology's status as a valid and recognized measurement in order to subsequently strengthen the prevention of occupational diseases among workers. A very necessary part of the research was the development of a new SW application for datalogger data analysis. This application provides the datalogger's user with a clear graphical output. A graph within it specifies the level of local muscular load. This paper presents a theoretical and experimental evaluation of the equipment being developed (the datalogger) and its validation with the existing certified methodology called electromyography (EMG). The results of the correlations of both measurements while evaluating the local muscular load are analyzed within this article. © 2018 Elsevier Ltd | en |
utb.faculty | Faculty of Management and Economics | |
dc.identifier.uri | http://hdl.handle.net/10563/1007788 | |
utb.identifier.obdid | 43878826 | |
utb.identifier.scopus | 2-s2.0-85042722872 | |
utb.identifier.wok | 000428720700010 | |
utb.identifier.coden | MSRMD | |
utb.source | j-scopus | |
dc.date.accessioned | 2018-04-23T15:01:44Z | |
dc.date.available | 2018-04-23T15:01:44Z | |
dc.description.sponsorship | Internal Grant Agency of FaME TBU [RO/2016/03, VaV-IP-RO/2016/03, IGA/FaME/2015/030] | |
utb.contributor.internalauthor | Tuček, David | |
utb.contributor.internalauthor | Tučková, Zuzana | |
utb.fulltext.affiliation | Vieroslav Molnár a,* , Gabriel Fedorko a , David Tuček b , Zuzana Tučková b a Technical University of Košice, Park Komenského 14, 042 00 Košice, Slovak Republic b Tomas Bata University in Zlín, nám. T. G. Masaryka 5555, 760 01 Zlín, Czech Republic * Corresponding author. E-mail address: [email protected] (V. Molnár). | |
utb.fulltext.dates | Received 26 October 2017; Received in revised form 29 January 2018; Accepted 6 February 2018; Available online 25 February 2018 | |
utb.fulltext.references | [1] T. Lerher, M. Edl, B. Rosi, Energy efficiency model for the mini-load automated storage and retrieval systems, Int. J. Adv. Manuf. Technol. 1–4 (2014) 97–115. [2] M. Halaki, Electromyography (EMG), Cl. Notes (2004) 1–15, http://dx.doi.org/10.1201/9780203489925.ch19/n10.1201/9780203489925.ch19. [3] G.Å. Hansson, C. Nordander, P. Asterland, K. Ohlsson, U. Strömberg, S. Skerfving, et al., Sensitivity of trapezius electromyography to differences between work tasks – influence of gap definition and normalisation methods, J. Electromyogr. Kinesiol. 10 (2000) 103–115, http://dx.doi.org/10.1016/S1050-6411(99)00030-9. [4] Y. Konno, Studies on muscular strength-myogram (MSMG) Part 1, a new device of apparatus for measuring muscular strength-myogram, Sangyo Igaku 18 (1976) 383–390, http://dx.doi.org/10.1539/joh1959.18.383. [5] T. Öberg, Muscle fatigue and calibration of EMG measurements, J. Electromyogr. Kinesiol. 5 (1995) 239–243, http://dx.doi.org/10.1016/1050-6411(96)85582-9. [6] D.L. Rickert, M. Halaki, K.A. Ginn, M.S. Barrett, B.J. Ackermann, The use of fine-wire EMG to investigate shoulder muscle recruitment patterns during cello bowing: the results of a pilot study, J. Electromyogr. Kinesiol. 23 (2013) 1261–1268, http://dx.doi.org/10.1016/j.jelekin.2013.07.013. [7] L. Philipson, R. Sorbye, P. Larsson, Muscular load levels in performing musicians as monitored by quantitative electromyography, Med. Probl. Perform. Art. 5 (1990) 79–82 http://www.sciandmed.com/mppa/journalviewer.aspx?issue=1136&article=1370&action=1%255Cnpapers3://publication/uuid/E3D0FF40-DAD2-4862-B999-E16293791121. [8] B.O. Christensen, L.R. Damgaard, J.S. Berg, T.S. Andersen, S. Aagaard, J.M. Hasenkam, Quantitative evaluation of a novel sensor for measuring muscular tissue flow and gases, Scand. Cardiovasc. J. 40 (2006) 374–379, http://dx.doi.org/10.1080/14017430601004261. [9] S. Bandinelli, E. Benvenuti, I. Del Lungo, M. Baccini, F. Benvenuti, A. Di Iorio, et al., Measuring muscular strength of the lower limbs by hand-held dynamometer: a standard protocol, Aging Clin. Exp. Res. 11 (1999) 287–293, http://dx.doi.org/10.1007/BF03339802. [10] S. Niinimäki, S. Söderling, J.-A. Junno, M. Finnilä, M. Niskanen, Cortical bone thickness can adapt locally to muscular loading while changing with age, HOMO – J. Comp. Hum. Biol. 64 (2013) 474–490, http://dx.doi.org/10.1016/j.jchb.2013.07.004. [11] Z. Abusara, R. Krawetz, B. Steele, M. DuVall, T. Schmidt, W. Herzog, Muscular loading of joints triggers cellular secretion of PRG4 into the joint fluid, J. Biomech. 46 (2013) 1225–1230, http://dx.doi.org/10.1016/j.jbiomech.2013.02.027. [12] M. Stål, G.-Å. Hansson, U. Moritz, Upper extremity muscular load during machine milking, Int. J. Ind. Ergon. 26 (2000) 9–17, http://dx.doi.org/10.1016/S0169-8141(99)00059-1. [13] L. Niemi-Murola, M. Paloheimo, Feasibility of electromyography (sEMG) in measuring muscular activity during spinal anaesthesia in patients undergoing knee arthroplasty, Acta Anaesthesiol. Scand. 49 (2005) 558–562, http://dx.doi.org/10.1111/j.1399-6576.2005.00603.x. [14] D. Tuček, J. Dlabač, Competence Management in Industrial Engineering Departments in the Czech Republic, in: Proc. 14th Eur. Conf. Knowl. Manag., Kaunas University of Technology, Lithuania, Kaunas, 2013, pp. 722–731. [15] H. Bubb, B. Spanner-Ulmer, Industrial engineering and ergonomics: visions, concepts, methods and tools, in: C.M. Schlick (Ed.), Ind. Eng. Ergon. Visions, Concepts, Methods Tools, Springer - Verlag, Berlin Heidelberg, 2009, pp. 481–498. [16] H.L. Hales, B. Andersen, Planning Manufacturing Cells, Society of Manufacturing Engineers, Dearborn, 2002. [17] Getacentrum, n.d. < http://english.getacentrum.cz/emg-holter/ > . [18] SZU, n.d. < http://www.szu.cz/uploads/NZP/Hlaseni_odhlaseni_2014.pdf > . [19] P.J. Sheahan, S.L. Cashaback, Joshua G.A. Fischer, Evaluating the ergonomic benefit of a wrist brace on wrist posture, muscle activity, rotational stiffness, and peak shovel-ground impact force during a simulated tree-planting task, Hum. Factors J. Hum. Factors Ergon. Soc. 59 (2017) 911–924, http://dx.doi.org/10.1177/0018720817708084. | |
utb.fulltext.sponsorship | The authors are also thankful to the Internal Grant Agency of FaME TBU No. RO/2016/03, VaV-IP-RO/2016/03 (“Parameters modelling for effective production and administrative processes in industrial companies based on Industry 4.0 concept”) and Internal Grant Agency of FaME TBU No. IGA/FaME/2015/030 (Evaluation model of ergonomic principles in Czech companies) for the financial support needed to carry out this research. | |
utb.scopus.affiliation | Technical University of Košice, Park Komenského 14, Košice, Slovakia; Tomas Bata University in Zlín, nám. T. G. Masaryka 5555, Zlín, Czech Republic | |
utb.fulltext.projects | RO/2016/03 | |
utb.fulltext.projects | VaV-IP-RO/2016/03 | |
utb.fulltext.projects | IGA/FaME/2015/030 |