Kontaktujte nás | Jazyk: čeština English
dc.title | Use of polynomial approach for control of heat exchanger | en |
dc.contributor.author | Bobál, Vladimír | |
dc.contributor.author | Kubalčík, Marek | |
dc.contributor.author | Dostál, Petr | |
dc.contributor.author | Talaš, Stanislav | |
dc.relation.ispartof | Proceedings of the 2015 20th International Conference on Process Control (PC) | |
dc.identifier.isbn | 978-1-4673-6627-4 | |
dc.date.issued | 2015 | |
utb.relation.volume | 2015-July | |
dc.citation.spage | 170 | |
dc.citation.epage | 175 | |
dc.event.title | 20th International Conference on Process Control (PC) | |
dc.event.location | Štrbské pleso | |
utb.event.state-en | Slovakia | |
utb.event.state-cs | Slovensko | |
dc.event.sdate | 2015-06-09 | |
dc.event.edate | 2015-06-12 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | |
dc.identifier.doi | 10.1109/PC.2015.7169957 | |
dc.relation.uri | http://ieeexplore.ieee.org/document/7169957/ | |
dc.subject | time-delay systems | en |
dc.subject | Smith Predictor | en |
dc.subject | polynomial methods | en |
dc.subject | 2DOF control | en |
dc.subject | heat exchanger | en |
dc.description.abstract | A heat exchanger is a specialized device that assists in the transfer of heat from one fluid to the other. In some cases, a solid wall may separate the fluids and prevent them from mixing. In other designs, the fluids may be in direct contact with each other. Heat exchangers are requisite in a range of industrial technologies, particularly in the energetic, chemical, polymer and rubber industry. Heat exchange processes often contain time-delay. This paper deals with design of a universal digital control algorithm for control of a great deal of processes with time-delay. This algorithm is realized by the digital Smith Predictor based on polynomial approach - Linear Quadratic (LQ) method. For a minimization of the LQ criterion is used spectral factorization. The designed polynomial controllers were verified not only by simulation but also by a real-time control of an experimental laboratory heat exchanger. | en |
utb.faculty | Faculty of Applied Informatics | |
dc.identifier.uri | http://hdl.handle.net/10563/1006706 | |
utb.identifier.obdid | 43874148 | |
utb.identifier.scopus | 2-s2.0-84990882548 | |
utb.identifier.wok | 000380509500029 | |
utb.source | d-wok | |
dc.date.accessioned | 2016-10-25T12:38:07Z | |
dc.date.available | 2016-10-25T12:38:07Z | |
utb.contributor.internalauthor | Bobál, Vladimír | |
utb.contributor.internalauthor | Kubalčík, Marek | |
utb.contributor.internalauthor | Dostál, Petr | |
utb.contributor.internalauthor | Talaš, Stanislav | |
utb.fulltext.affiliation | Vladimír Bobál, Marek Kubalčík, Petr Dostál, Stanislav Talaš Department of Process Control, Faculty of Applied Informatics, Tomas Bata University in Zlin, Zlin, Czech Republic [email protected], [email protected], [email protected], [email protected] | |
utb.fulltext.references | - | |
utb.fulltext.sponsorship | - | |
utb.fulltext.projects | - |