Kontaktujte nás | Jazyk: čeština English
dc.title | Improving sensitivity of the polyurethane/CNT laminate strain sensor by controlled mechanical preload | en |
dc.contributor.author | Slobodian, Petr | |
dc.contributor.author | Olejník, Robert | |
dc.contributor.author | Matyáš, Jiří | |
dc.contributor.author | Babar, Dipak Gorakh | |
dc.relation.ispartof | IOP Conference Series: Materials Science and Engineering | |
dc.identifier.issn | 1757-8981 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2016 | |
utb.relation.volume | 108 | |
utb.relation.issue | 1 | |
dc.event.title | 5th International Conference on Materials and Applications for Sensors and Transducers, IC-MAST 2015 | |
dc.event.location | Mykonos | |
utb.event.state-en | Greece | |
utb.event.state-cs | Řecko | |
dc.event.sdate | 2015-09-27 | |
dc.event.edate | 2015-09-30 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | Institute of Physics Publishing | |
dc.identifier.doi | 10.1088/1757-899X/108/1/012022 | |
dc.relation.uri | http://iopscience.iop.org/article/10.1088/1757-899X/108/1/012022/meta | |
dc.description.abstract | This article describes strain detection potential of polyurethane/CNT layered composite and further possible enhance of its sensitivity to strain, expressed by value of gauge factor, GF, employing its controlled mechanical preload. In course of its fabrication a non-woven polyurethane membrane made by electro spinning was used as filtering membrane for CNT aqueous dispersion. Final CNT polyurethane laminate composite is prepared by compression molding. Produced polyurethane/CNT composite laminate is electrically conductive and high elastic. Its elongation leads to change of its macroscopic electrical resistance. Changes in resistance are further reversible, reproducible and can monitor deformation in real time. Gauge factor reaches very high values around 8 for strain reaching 3.5% comparing with conventional metallic strain gauges. Finally, controlled mechanical preload significantly increases value of GF. For example for value of 8.1% of preload value of GF reaches 23.3 for strain 3.5%. © Published under licence by IOP Publishing Ltd. | en |
utb.faculty | University Institute | |
dc.identifier.uri | http://hdl.handle.net/10563/1006407 | |
utb.identifier.obdid | 43875181 | |
utb.identifier.scopus | 2-s2.0-84964790196 | |
utb.identifier.wok | 000376204700022 | |
utb.source | d-scopus | |
dc.date.accessioned | 2016-07-26T14:58:27Z | |
dc.date.available | 2016-07-26T14:58:27Z | |
dc.rights | Attribution 3.0 Unported | |
dc.rights.uri | https://creativecommons.org/licenses/by/3.0/ | |
utb.ou | Centre of Polymer Systems | |
utb.contributor.internalauthor | Slobodian, Petr | |
utb.contributor.internalauthor | Olejník, Robert | |
utb.contributor.internalauthor | Matyáš, Jiří | |
utb.contributor.internalauthor | Babar, Dipak Gorakh | |
utb.fulltext.affiliation | Petr Slobodian, Robert Olejnik, Jiri Matyas, Dipak Gorakh Babar Centre of Polymer Systems, University Institute, Tomas Bata University, Nad Ovcirnou 3685, 760 01 Zlin, Czech Republic Corresponding author’s e-mail address: [email protected] | |
utb.fulltext.dates | - | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.ou | Centre of Polymer Systems | |
utb.fulltext.ou | Centre of Polymer Systems | |
utb.fulltext.ou | Centre of Polymer Systems | |
utb.fulltext.ou | Centre of Polymer Systems |